3
Switched from multimeter to oscilloscope for bus troubleshooting after 8 years
Used to chase intermittent ARINC 429 faults with a DMM for years. Picked up a cheap Rigol scope last month and found a voltage droop on the 28V line in under 2 minutes. Anyone else make the switch and wonder how you got by before?
2 comments
Log in to join the discussion
Log In2 Comments
thomas27510d ago
Haven't you ever fixed more than what's actually broken by looking too close at a signal that wasn't really causing the problem?
8