Vent: I fought the chamber test for 3 weeks and now I'm doing it with a dead surface
Last month up at the pump station job on the Sacramento River, our tender kept pushing me to run the chamber test with the surface at 40 psi instead of dead surface. I dug in hard. I've been diving 11 seasons and every outfit I came up in taught dead surface or nothing, so I figured he was cutting corners to save a couple hours on the schedule. We went back and forth for 3 weeks, me pulling my hat off at the ladder every morning and him ticking boxes on the penetration plan. Then a boiler tech named Ray, who I trust more than any supervisor, pointed out that the whole point of the test is keeping the tissue pressure gradient the same as your working dive, and if the dive had surface support pressure then a dead surface test is the one that's lying to you. So I ran it his way on Tuesday, 40 psi on the wheel, and the readings finally lined up with what my body was telling me on the bottom. I still think the outfit that trained me had a good reason for the old rule, and I'm not saying change everything, but your mileage may vary depending on the job plan. Anybody else get the surface pressure argument hammered out of them by a guy they trust? Curious what your medical examiner says about it.