Shoutout to the finisher in Reno who showed me the hose trick I wish I'd known 12 years ago
For years I ran my finishing hose wide open and just tried to be careful, and I ate a 4 inch blowout on a 900 sq ft pour in Sparks last spring that cost me half a day. A guy named Dale on that job showed me to crack the valve to about a quarter turn and keep a wet sponge on the nozzle so the hose never whips. I've run it that way on every pour since and haven't lost a single edge to a stray hose stream. Took me 12 years to change one habit, and it was a $0 fix. What little setup tricks did you pick up way later than you should have?