Thought anti two-block was a gimmick until the alarm saved my boom in Norfolk
I ran a 60 ton for 12 years and always figured the anti two-block warning was just nanny tech, but it went off on a tilt-up panel pick in Norfolk where I swear I had 6 feet of head room. Turns out my line was riding up on the drum and I had maybe 8 inches left, and the rigging guy backed me up on it. Anyone running older cranes without that alarm, what do you use instead, just a spotter with a hand signal?
Yeah I ran a 50 ton for years with nothing but a guy on the ground hollering at me, and that works until it doesn't. The problem is a spotter can't always see the drum, and that's usually where the mess starts, line stacking up or jumping a groove so the boom tip is higher than your load chart wants. Get in the habit of eyeballing your drum between picks and keep a paint mark on the cable so you can see how much you got left at a glance. On the old stuff a lot of guys run a simple anti two block switch wired to a buzzer, it's cheap and it beats trusting one guy's eyes. Also don't fight the alarm on the new iron, when it goes off you usually got less room than your gut says you do.